Patient information: uses, side effects, how to take - Ultra-Technekow V4

Directions for Use of the Technetium Tc 99m Generator

NOTE 1: Immediately upon delivery, the generator should be placed within a minimum of one-inch of lead shielding in such a manner

so as to minimize radiation exposure to attending personnel.

NOTE 2: Wear waterproof gloves during the elution procedure and during subsequent reconstitution of kits with the eluate.

NOTE 3: Use a shielded syringe to withdraw patient dose or to transfer Sodium Pertechnetate Tc 99m into mixing vials during kit

reconstitution.

NOTE 4: The needles in the generator are sterile beneath their covers, and the generator has been cleaned underneath the top cover.

Additional disinfection of these areas with agents containing alcohol may unfavorably influence the Tc-99m yield.

Eluting the generator every 24 hours will provide optimal amounts of Sodium Pertechnetate Tc 99m. However, the generator may be eluted whenever sufficient amounts of technetium Tc-99m have accumulated within the column.

For Example

Time After

First Elution (hrs.)

Approximate Yield

(% of First Elution)

110
219
327
435
541
647

Elution

  1. 1. Lift the generator by its handle and place it inside the auxiliary shield. Move the handle so that it is not covering the generator top by pushing it off to the side in between the generator and the auxiliary shield.
  2. 2. Remove and store the elution hood cover. Place the auxiliary shield top onto the top of the generator and align it with the elution hood.
  3. 3. Remove and store the tip cap plugs from the needles.
  4. 4. Remove the flip-top cap of the eluant vial; disinfect the stopper with a bacteriocide such as 70% isopropyl alcohol, allowing the stopper to dry before use. Invert the eluant vial and place stopper first into the saline vial alignment insert. Place the saline vial alignment insert and vial into the saline port of the auxiliary shield top and firmly push down the eluant vial until the stopper is punctured and seated at the base of the eluant needles.
  5. 5. Place the saline shield on top of the auxiliary shield top to cover the eluant vial.
  6. 6. Remove the flip-top cap of an evacuated vial; disinfect the stopper, allowing the stopper to dry before use. Place the evacuated vial into the elution tool.
  7. 7. Position the shielded evacuated vial by carefully lowering the elution tool into place on the elution needle. Piercing the septum of the evacuated vial with the elution needle will begin the elution process.
  8. 8. Wait until the evacuated vial has completely filled itself. This may take a few minutes. Never interrupt the elution by lifting the elution tool!
  9. 9. NOTE: Do not use generator eluate if its appearance is discolored, and discontinue use of the generator.
  10. 10. Remove the flip-top cap of the Technestat vial; disinfect the stopper, allowing the stopper to dry before use. Secure the Technestat vial into the Technestat vial holder.
  11. 11. Carefully remove the elution tool and replace with the shielded Technestat vial.
  12. 12. Determine the technetium Tc-99m concentration and molybdenum Mo-99 content for dispensing purposes. The generator eluate may be assayed using an appropriate detection system. The manufacturer’s instructions for operation of the instrument/equipment should be followed for measurement of Technetium Tc-99m and Molybdenum Mo-99 activity. NOTE: Molybdenum Mo-99 Breakthrough Limit- The acceptable limit is 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose in the Injection, at the time of administration (see USP, Sodium Pertechnetate Tc 99m Injection).
  13. 13. Determine the aluminum ion concentration of the eluate. NOTE: Aluminum Ion Breakthrough Limit- The acceptable limit is not more than 10 micrograms per milliliter of eluate (see USP, Sodium Pertechnetate Tc 99m Injection).

Subsequent Elutions

  1. 1. Remove the saline shield and then remove saline vial alignment insert from the saline port to remove the eluant vial from the eluant needles. Remove the vial from the saline vial alignment insert and reuse the saline vial alignment insert for subsequent elutions.
  2. 2. Remove the shielded Technestat vial by carefully lifting the Technestat vial shield from the elution needle.
  3. 3. Repeat steps 4 through 12 of the Elution procedure above.

Vacuum Loss

If the vacuum in the collecting vial is lost, do not attempt to re-evacuate the vial, but discard and use a new collecting vial.

Expired Generator Disposal

  1. 1. Following the life of the generator, remove and dispose of the used Technestat vial and the eluant vial.
  2. 2. Cover the elution and eluant needles with the stored tip cap plugs.
  3. 3. Place the stored elution hood cover onto the top of the generator.
  4. 4. The intact generator assembly should be either returned to Curium US LLC or disposed of in accordance with applicable regulations.

This generator may be received, used and administered only by authorized persons in designated clinical settings. Its receipt, storage, use, transfer and disposal are subject to the regulations and/or appropriate licenses of local competent official organizations.

©2022 Curium US LLC. Ultra-Technekow TM, Technestat TM, Curium™, and the Curium logo are trademarks of a Curium company.

Manufactured by:

Curium US LLC

Maryland Heights, MO 63043 USA

Made in USA

A901IS

Revised 5/2022

STERILE

CURIUM™

About this document

Source: FDA drug labeling via NLM DailyMed · Application number: NDA 017243 · View the label on DailyMed

Revision date stated in the text: May 2022

Found a mistake? Write to us via the contact page.

The information on this site does not replace the advice of a doctor or pharmacist.

Drug information for Ultra-Technekow V4

Rx or OTC
Prescription (Rx)?
  • This drug is available only with a prescription from a licensed healthcare provider.
  • Rx
Active ingredient Technetium Tc-99m sodium pertechnetate
Dosage form Injection, solution
Route Intravenous
Marketing status listed in the FDA NDC Directory
Company (applicant) CURIUM
FDA approval NDA 017243New Drug Application (NDA) Approved November 23, 1973
Reference listed drug This is the reference listed drug (RLD) that generics are compared with.
Manufacturers 1 labelers list this drug on DailyMed
Packages (NDC)
Package
1 Ci – 1 in 1 carton NDC 69945-010-03
14 Ci – 1 in 1 carton NDC 69945-140-13
16 Ci – 1 in 1 carton NDC 69945-160-14
19 Ci – 1 in 1 carton NDC 69945-190-15
5 Ci – 1 in 1 carton NDC 69945-051-09
1.5 Ci – 1 in 1 carton NDC 69945-015-04
2 Ci – 1 in 1 carton NDC 69945-020-05
2.5 Ci – 1 in 1 carton NDC 69945-025-06
3 Ci – 1 in 1 carton NDC 69945-030-07
3.5 Ci – 1 in 1 carton NDC 69945-035-08
6 Ci – 1 in 1 carton NDC 69945-060-10
7.5 Ci – 1 in 1 carton NDC 69945-075-11
Show more packages (1)+
11 Ci – 1 in 1 carton NDC 69945-110-12

Source: FDA drug labeling via NLM DailyMed, data as of October 31, 2026. FDA data (DailyMed, Orange Book, Drug Shortages, enforcement reports). Not a substitute for the advice of a doctor or pharmacist.