DESCRIPTION

The Ultra-Technekow ™V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution.

This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation.

The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions.

Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration.

Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.

Physical Characteristics

Technetium Tc-99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 1.

Table 1. Principal Radiation Emission Data

Radiation

Mean Percent

Per

Disintegration

Energy

(keV)

Gamma-289.07140.5

External Radiation

The specific gamma ray constant for technetium Tc-99m is 0.795 R/hr-mCi at 1 cm. The first half-value layer is 0.023 cm of lead (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of 0.27 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1000.

Table 2. Radiation Attenuation by Lead Shielding

Shield

Thickness (Pb) cm

Coefficient

of Attenuation

0.0230.5
0.0910 -1
0.1810 -2
0.2710 -3

Molybdenum Mo-99 decays to technetium Tc-99m with a molybdenum Mo-99 half-life of 2.75 days, or 66 hours (see Table 3). The physical decay characteristics of molybdenum Mo-99 are such that only 88.6% of the decaying molybdenum Mo-99 atoms form technetium Tc-99m. Generator elutions may be made at any time, but the amount of technetium Tc-99m available will depend on the interval measured from the last elution. Approximately 47% of the maximum available technetium Tc-99m is reached after 6 hours and 95% after 23 hours. To correct for physical decay of molybdenum Mo-99 and technetium Tc-99m, the fractions that remain at selected intervals of time are shown in Tables 3 and 4.

Table 3. Physical Decay Chart; Molybdenum Mo-99, Half-Life 66 Hours

DaysPercent RemainingDaysPercent Remaining
0100108
178116
260125
347134
437143
528152
622200.6
717250.2
813300.05
910

Table 4. Physical Decay Chart; Technetium Tc-99m, Half-Life 6 Hours

Hours

Percent

Remaining

Hours

Percent

Remaining

0*100935
1891032
2791128
3711225
4631420
5561616
6501813
745246
840

*Calibration Time

CLINICAL PHARMACOLOGY

The pertechnetate ion distributes in the body similarly to the iodide ion but is not organified when trapped in the thyroid gland. Pertechnetate concentrates in the thyroid gland, salivary glands, stomach and choroid plexus. After intravenous administration it gradually equilibrates with the extracellular space. A fraction is promptly excreted via the kidneys.

Following the administration of Sodium Pertechnetate Tc 99m as an eye drop, the drug mixes with tears within the conjunctival space. Within seconds to minutes it leaves the conjunctival space and escapes into the inferior meatus of the nose through the nasolacrimal drainage system. During this process the pertechnetate ion passes through the canaliculi, the lacrimal sac and the nasolacrimal duct. In the event of any anatomical or functional blockage of the drainage system there will be a backflow resulting in tearing (epiphora). Thus the pertechnetate escapes the conjunctival space in the tears.

While the major part of the pertechnetate escapes within a few minutes of normal drainage and tearing, it has been documented that there is some degree of transconjunctival absorption with turnover of 1.5% per minute in normal individuals, 2.1% per minute in patients without any sac and 2.7% per minute in patients with inflamed conjunctiva due to chronic dacryocystitis. Individual values may vary but these rates are probably representative and indicate that the maximum possible pertechnetate absorbed will remain below one thousandth of that used in other routine diagnostic procedures.

INDICATIONS AND USAGE

The Ultra-Technekow™ V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits.

Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:

Thyroid Imaging

Salivary Gland Imaging

Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux

Nasolacrimal Drainage System Imaging (dacryoscintigraphy)

Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:

Thyroid Imaging

Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux

CONTRAINDICATIONS

None.

WARNINGS

Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients.

Long-term cumulative radiation exposure may be associated with an increased risk of cancer.

Only use generator eluant specified for use with the Ultra-Technekow ™V4 Generator. Do not use any other generator eluant or saline from any other source.

PRECAUTIONS

Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides.

As in the use of any radioactive material, care should be taken to minimize radiation exposure to the patient consistent with proper patient management and to ensure minimum radiation exposure to occupational workers.

After the termination of the nasolacrimal imaging procedure, blowing the nose and washing the eyes with sterile distilled water or an isotonic sodium chloride solution will further minimize the radiation dose.

Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from time of generator elution.

Carcinogenesis, Mutagenesis, Impairment of Fertility

No long-term animal studies have been performed to evaluate carcinogenic or mutagenic potential or whether Sodium Pertechnetate Tc 99m may affect fertility in males or females.

Pregnancy

In animal reproductive studies, Sodium Pertechnetate Tc 99m (as free pertechnetate) has been shown to cross the placental barrier. It is not known whether Sodium Pertechnetate Tc 99m can cause fetal harm when administered to a pregnant woman or can affect reproductive capacity.

Sodium Pertechnetate Tc 99m should be given to pregnant women only if the expected benefits to be gained clearly outweigh the potential hazards.

Ideally, examinations using radiopharmaceutical drug products - especially those elective in nature - of women of childbearing capability should be performed during the first ten days following the onset of menses.

Nursing Mothers

Technetium Tc-99m is excreted in human milk during lactation, therefore, formula-feedings should be substituted for breast-feedings.

Pediatric Use

See INDICATIONS AND USAGE and DOSAGE AND ADMINISTRATION sections. Also see the description of additional risk under WARNINGS .

ADVERSE REACTIONS

Allergic reactions including anaphylaxis have been reported infrequently following the administration of Sodium Pertechnetate Tc 99m.

DOSAGE AND ADMINISTRATION

Sodium Pertechnetate Tc 99m is administered by intravenous injection. When imaging the nasolacrimal drainage system, instill the Sodium Pertechnetate Tc 99m by the use of a device such as a micropipette or similar method which will ensure the accuracy of the dose.

For imaging the urinary bladder and ureters (direct isotopic cystography), the Sodium Pertechnetate Tc 99m is administered by direct instillation aseptically into the bladder via a urethral catheter, following which the catheter is flushed with approximately 200 mL of sterile saline directly into the bladder.

The suggested dose ranges employed for various diagnostic indications in the average ADULT PATIENT (70 kg) are as follows:

Vesico-ureteral imaging: 18.5 to 37 MBq (0.5 to 1 mCi)

Thyroid gland imaging: 37 to 370 MBq (1 to 10 mCi)

Salivary gland imaging: 37 to 185 MBq (1 to 5 mCi)

Nasolacrimal drainage system: Maximum dose of 3.7 MBq (100 µCi)

The recommended dosages in PEDIATRIC PATIENTS are:

Vesico-ureteral imaging: 18.5 to 37 MBq (0.5 to 1 mCi)

Thyroid gland imaging: 2.22 to 2.96 MBq (60 to 80 µCi) per kg body weight

The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration.

Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. If the solution is discolored, discontinue use of the generator immediately. The solution to be administered as the patient dose should be clear, colorless, and contain no particulate matter.

Radiation Dosimetry

The estimated absorbed radiation doses to an average ADULTand PEDIATRICpatient from an intravenous injection of various doses of Sodium Pertechnetate Tc 99m distributed uniformly in the total body are shown in Tables 5 and 6.

Table 5. Absorbed Radiation Doses from Intravenous Injection

OrganAbsorbed Radiation Dose (mGy) for a 1110 MBq (30mCi) dose
Adrenals4.1
Urinary Bladder Wall20
Bone Surfaces6.2
Brain2.2
Breasts2
Gallbladder Wall8.3
Stomach Wall29
Small Intestine18
ULI Wall63
LLI Wall23
Heart Wall3.5
Kidneys6
Liver4.7
Lungs2.9
Muscle3.6
Ovaries11
Pancreas6.3
Red Marrow4.1
Skin2
Spleen4.8
Testes3.1
Thymus2.7
Thyroid24
Uterus9
Remaining Tissues3.9
Effective Dose (mSv)14

To obtain radiation absorbed dose in rads (30 mCi dose) from the above table, divide individual organ values by a factor of 10 (does not apply for effective dose).

Table 6. Pediatric Absorbed Radiation Doses (mGy) from Intravenous Injection

Age15 years10 years5 years1 year
Administered activity in MBq (mCi)

1110

(30)

740

(20)

555

(15)

370

(10)

Organ
Adrenals5.35.46.27.1
Urinary Bladder Wall26221822
Bone Surfaces7.67.58.110
Brain2.83.13.74.5
Breasts2.62.63.24.1
Gallbladder Wall11121313
Stomach Wall38364359
Small Intestine22232630
ULI Wall8189110140
LLI Wall31334048
Heart Wall4.54.65.26.4
Kidneys7.26.97.88.5
Liver66.789.1
Lungs3.83.84.45.3
Muscle4.54.556
Ovaries14131417
Pancreas8.18.28.910
Red Marrow5.155.26
Skin2.52.63.23.8
Spleen666.77.8
Testes4.14.34.96
Thymus3.63.54.25.3
Thyroid40416781
Uterus11111214
Remaining Tissues4.84.85.46.4
Effective Dose (mSv)19192329

To obtain radiation absorbed dose in rads (30 mCi dose) from the above table, divide individual organ values by a factor of 10 (does not apply for effective dose).

The estimated absorbed radiation doses to an ADULT patient from the nasolacrimal imaging procedure using a maximum dose of 3.7 megabecquerels (100 microcuries) of Sodium Pertechnetate Tc 99m are shown in Table 7.

Table 7. Absorbed Radiation Doses from Dacryoscintigraphy

Tissue

3.7 MBq (100 µCi)

Dose of Sodium Pertechnetate Tc 99m

mGyrad

Eye Lens:

If lacrimal fluid turnover is 16%/min

0.1400.014

If lacrimal fluid

turnover is 100%/min

0.0220.002

If drainage

system is blocked

4.0200.402
Total Body*0.0110.001
Ovaries*0.0300.003
Testes*0.0090.001
Thyroid*0.1300.013

*Assuming no blockage of draining system.

In pediatric patients, an average 30 minute exposure to 37 MBq (1 mCi) of Tc-99m pertechnetate following instillation for direct cystography, will result in the following estimated radiation doses:

Table 8. Absorbed Radiation Doses from Cystography (PEDIATRIC)

AgeBladder wall dose, mGy (rad)

Gonadal dose,

mGy (rad)

1 year3.6 (0.36)0.15 (0.015)
5 years2.0 (0.2)0.095 (0.0095)
10 years1.3 (0.13)0.066 (0.0066)
15 years0.92 (0.092)0.046 (0.0046)

HOW SUPPLIED

The Ultra-Technekow ™V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.

Catalog No.

9010 37 gigabecquerels (1.0 curie)

NDC 69945-010-03

9015 55.5 gigabecquerels (1.5 curies)

NDC 69945-015-04

9020 74 gigabecquerels (2.0 curies)

NDC 69945-020-05

9025 92.5 gigabecquerels (2.5 curies)

NDC 69945-025-06

9030 111 gigabecquerels (3.0 curies)

NDC 69945-030-07

9035 129.5 gigabecquerels (3.5 curies)

NDC 69945-035-08

9051 185 gigabecquerels (5.0 curies)

NDC 69945-051-09

9060 222 gigabecquerels (6.0 curies)

NDC 69945-060-10

9075 277.5 gigabecquerels (7.5 curies)

NDC 69945-075-11

9110 407 gigabecquerels (11.0 curies)

NDC 69945-110-12

9140 518 gigabecquerels (14.0 curies)

NDC 69945-140-13

9160 592 gigabecquerels (16.0 curies)

NDC 69945-160-14

9190 703 gigabecquerels (19.0 curies)

NDC 69945-190-15

Each generator is supplied with the following components for the elution of the generator:

1 - Technestat ™Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic

1 - Package Insert

SUPPLIED SEPARATELY

30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with:

90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es)

90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es)

1 - Package Insert

30 - Generator Eluant, 0.9% Sodium Chloride Injection, sterile, non-pyrogenic, available in 5 mL, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. Each milliliter of Generator Eluant contains 9 milligrams of Sodium Chloride.

Storage

Store generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20° to 25°C (68° to 77°F) [see USP Controlled Room Temperature].

Expiration Date

The generator should not be used after the expiration date stated on the label.

The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.

Directions for Use of the Technetium Tc 99m Generator

NOTE 1: Immediately upon delivery, the generator should be placed within a minimum of one-inch of lead shielding in such a manner

so as to minimize radiation exposure to attending personnel.

NOTE 2: Wear waterproof gloves during the elution procedure and during subsequent reconstitution of kits with the eluate.

NOTE 3: Use a shielded syringe to withdraw patient dose or to transfer Sodium Pertechnetate Tc 99m into mixing vials during kit

reconstitution.

NOTE 4: The needles in the generator are sterile beneath their covers, and the generator has been cleaned underneath the top cover.

Additional disinfection of these areas with agents containing alcohol may unfavorably influence the Tc-99m yield.

Eluting the generator every 24 hours will provide optimal amounts of Sodium Pertechnetate Tc 99m. However, the generator may be eluted whenever sufficient amounts of technetium Tc-99m have accumulated within the column.

For Example

Time After

First Elution (hrs.)

Approximate Yield

(% of First Elution)

110
219
327
435
541
647

Elution

  1. 1. Lift the generator by its handle and place it inside the auxiliary shield. Move the handle so that it is not covering the generator top by pushing it off to the side in between the generator and the auxiliary shield.
  2. 2. Remove and store the elution hood cover. Place the auxiliary shield top onto the top of the generator and align it with the elution hood.
  3. 3. Remove and store the tip cap plugs from the needles.
  4. 4. Remove the flip-top cap of the eluant vial; disinfect the stopper with a bacteriocide such as 70% isopropyl alcohol, allowing the stopper to dry before use. Invert the eluant vial and place stopper first into the saline vial alignment insert. Place the saline vial alignment insert and vial into the saline port of the auxiliary shield top and firmly push down the eluant vial until the stopper is punctured and seated at the base of the eluant needles.
  5. 5. Place the saline shield on top of the auxiliary shield top to cover the eluant vial.
  6. 6. Remove the flip-top cap of an evacuated vial; disinfect the stopper, allowing the stopper to dry before use. Place the evacuated vial into the elution tool.
  7. 7. Position the shielded evacuated vial by carefully lowering the elution tool into place on the elution needle. Piercing the septum of the evacuated vial with the elution needle will begin the elution process.
  8. 8. Wait until the evacuated vial has completely filled itself. This may take a few minutes. Never interrupt the elution by lifting the elution tool!
  9. 9. NOTE: Do not use generator eluate if its appearance is discolored, and discontinue use of the generator.
  10. 10. Remove the flip-top cap of the Technestat vial; disinfect the stopper, allowing the stopper to dry before use. Secure the Technestat vial into the Technestat vial holder.
  11. 11. Carefully remove the elution tool and replace with the shielded Technestat vial.
  12. 12. Determine the technetium Tc-99m concentration and molybdenum Mo-99 content for dispensing purposes. The generator eluate may be assayed using an appropriate detection system. The manufacturer’s instructions for operation of the instrument/equipment should be followed for measurement of Technetium Tc-99m and Molybdenum Mo-99 activity. NOTE: Molybdenum Mo-99 Breakthrough Limit- The acceptable limit is 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose in the Injection, at the time of administration (see USP, Sodium Pertechnetate Tc 99m Injection).
  13. 13. Determine the aluminum ion concentration of the eluate. NOTE: Aluminum Ion Breakthrough Limit- The acceptable limit is not more than 10 micrograms per milliliter of eluate (see USP, Sodium Pertechnetate Tc 99m Injection).

Subsequent Elutions

  1. 1. Remove the saline shield and then remove saline vial alignment insert from the saline port to remove the eluant vial from the eluant needles. Remove the vial from the saline vial alignment insert and reuse the saline vial alignment insert for subsequent elutions.
  2. 2. Remove the shielded Technestat vial by carefully lifting the Technestat vial shield from the elution needle.
  3. 3. Repeat steps 4 through 12 of the Elution procedure above.

Vacuum Loss

If the vacuum in the collecting vial is lost, do not attempt to re-evacuate the vial, but discard and use a new collecting vial.

Expired Generator Disposal

  1. 1. Following the life of the generator, remove and dispose of the used Technestat vial and the eluant vial.
  2. 2. Cover the elution and eluant needles with the stored tip cap plugs.
  3. 3. Place the stored elution hood cover onto the top of the generator.
  4. 4. The intact generator assembly should be either returned to Curium US LLC or disposed of in accordance with applicable regulations.

This generator may be received, used and administered only by authorized persons in designated clinical settings. Its receipt, storage, use, transfer and disposal are subject to the regulations and/or appropriate licenses of local competent official organizations.

©2022 Curium US LLC. Ultra-Technekow TM, Technestat TM, Curium™, and the Curium logo are trademarks of a Curium company.

Manufactured by:

Curium US LLC

Maryland Heights, MO 63043 USA

Made in USA

A901IS

Revised 5/2022

STERILE

CURIUM™

About this document

Source: FDA drug labeling via NLM DailyMed · Application number: NDA 017243 · View the label on DailyMed

Revision date stated in the text: May 2022

Found a mistake? Write to us via the contact page.

The information on this site does not replace the advice of a doctor or pharmacist.

Drug information for Ultra-Technekow V4

Rx or OTC
Prescription (Rx)?
  • This drug is available only with a prescription from a licensed healthcare provider.
  • Rx
Active ingredient Technetium Tc-99m sodium pertechnetate
Dosage form Injection, solution
Route Intravenous
Marketing status listed in the FDA NDC Directory
Company (applicant) CURIUM
FDA approval NDA 017243New Drug Application (NDA) Approved November 23, 1973
Reference listed drug This is the reference listed drug (RLD) that generics are compared with.
Manufacturers 1 labelers list this drug on DailyMed
Packages (NDC)
Package
1 Ci – 1 in 1 carton NDC 69945-010-03
14 Ci – 1 in 1 carton NDC 69945-140-13
16 Ci – 1 in 1 carton NDC 69945-160-14
19 Ci – 1 in 1 carton NDC 69945-190-15
5 Ci – 1 in 1 carton NDC 69945-051-09
1.5 Ci – 1 in 1 carton NDC 69945-015-04
2 Ci – 1 in 1 carton NDC 69945-020-05
2.5 Ci – 1 in 1 carton NDC 69945-025-06
3 Ci – 1 in 1 carton NDC 69945-030-07
3.5 Ci – 1 in 1 carton NDC 69945-035-08
6 Ci – 1 in 1 carton NDC 69945-060-10
7.5 Ci – 1 in 1 carton NDC 69945-075-11
Show more packages (1)+
11 Ci – 1 in 1 carton NDC 69945-110-12

Source: FDA drug labeling via NLM DailyMed, data as of October 31, 2026. FDA data (DailyMed, Orange Book, Drug Shortages, enforcement reports). Not a substitute for the advice of a doctor or pharmacist.