Patient information: uses, side effects, how to take - Morphine Injection
INSTRUCTIONS FOR USE
Figure 1: Outer Packaging (MicroVault) and Prefilled Syringe
NOTES:
Do not introduce any other fluid into the syringe at any time.
Do not dilute for IV push.
Do not re-sterilize the syringe.
Do not use this product on a sterile field.
This product is for single dose only.
1.
Once removed from the bundle, inspect the outer packaging by verifying:
- Integrity of the tube and the cap.
- Tamper evident seal is intact (outer shrink wrap is not broken).
Do not use if the outer packaging has been damaged.
2. Hold the outer packaging with both hands. To break the tamper evident seal, hold the tube and the cap close to the seal, and twist until broken. (See Figure 2)
Figure 2
3. Remove the cap of the outer packaging by pulling it straight away from the tube to avoid dislodging the plunger rod of the syringe. (See Figure 3)
Figure 3
4. Remove the syringe from the tube.
5. Visually inspect the syringe. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration, whenever solution and container permit.
6. Twist off the syringe tip cap. Do not remove the plastic wrap label around the luer lock collar. (See Figure 4)
Figure 4
7. Expel air bubble(s). Adjust the dose (if applicable).
8. Administer the dose ensuring that pressure is maintained on the plunger rod during the entire administration.
9. Discard the used syringe into an appropriate receptacle.
For more information concerning this drug, please call Fresenius Kabi USA, LLC at 1-800-551-7176.
To report SUSPECTED ADVERSE REACTIONS, contact Fresenius Kabi USA, LLC at 1-800-551-7176 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.
The brand names mentioned in this document are the trademarks of their respective owners.
U.S. Patents 9072781, 9192608, 10213424, 9731082, 10661018, 11426522, 10064998, 10792431, 10814059, and 11400206
NDA 204223New Drug Application (NDA)
Approved October 30, 2013
Reference listed drug
This is the reference listed drug (RLD) that generics are compared with.
Manufacturers
6 labelers list this drug on DailyMed
Drug shortage
Current since November 3, 2026
Recalls
August 4, 2026: Class I recall: Labeling: Label Mixup: MicroVault labeled as Morphine 2 mg/1 mL, contains a Prefilled Syringe of Dilaudid 0.5 mg/0.5 mL.
Packages (NDC)
Package
1 mg/0.5 mL – 0.5 ml in 1 syringe, glass / 10 in 1 carton
NDC 76045-238-01
2 mg/mL – 1 ml in 1 syringe, glass / 10 in 1 carton
NDC 76045-004-01
4 mg/mL – 1 ml in 1 syringe, glass / 10 in 1 carton
NDC 76045-005-01
5 mg/mL – 1 ml in 1 syringe, glass / 10 in 1 carton
NDC 76045-006-01
8 mg/mL – 1 ml in 1 syringe, glass / 10 in 1 carton
NDC 76045-007-01
10 mg/mL – 1 ml in 1 syringe, glass / 10 in 1 carton
NDC 76045-008-01
Source: FDA drug labeling via NLM DailyMed, data as of November 5, 2026. FDA data (DailyMed, Orange Book, Drug Shortages, enforcement reports). Not a substitute for the advice of a doctor or pharmacist.