INSTRUCTIONS FOR USE
CAUTION: Certain glass syringes may malfunction, break or clog when connected to some Needleless Luer Access Devices (NLADs) and needles. This syringe has a larger internal syringe tip and an external collar (luer collar). The external collar must remain attached to the syringe. (See Figure 1) Spontaneous disconnection of this glass syringe from needles and NLADs with leakage of drug product may occur. Assure that the needle or NLAD is securely attached before beginning the injection. Visually inspect the glass syringe-needle or glass syringe–NLAD connection before and during drug administration.

Diazepam injection may be administered intramuscularly or intravenously. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit.
- 1. Inspect the outer packaging (plastic tube) and the syringe label by verifying:
- - plastic tube integrity
- - drug name
- - drug strength
- - fill volume
- - route of administration
- - expiration date to be sure that the drug has not expired
- - sterile field applicability
Do not use if package has been damaged.
- 2. Open the outer packaging and remove the syringe from the tube.
- 3. Perform visual inspection on the syringe by verifying:
- - absence of syringe damage
- - absence of external particles
- - absence of internal particles
- - proper drug color
- 4. Push plunger rod slightly to break the stopper loose while tip cap is still on.
- 5. Remove tip cap by twisting it off. (See Figure 2)

- 6. Discard the tip cap.
- 7. Expel air bubble.
- 8. Adjust dose into sterile material (if applicable).
- 9. Connect the syringe to an appropriate injection connection depending on the route of administration.
- - Before injection, ensure that the syringe is securely attached to the needle or needleless luer access device (NLAD).
- 10. Depress plunger rod to deliver medication. Ensure that pressure is maintained on the plunger rod during the entire administration.
- 11. Remove syringe from NLAD (if applicable) and discard into appropriate receptacle.
When a needle is connected to the syringe, to prevent needle-stick injuries, needles must not be recapped.
NOTES:
- All steps must be done sequentially
- Do not autoclave syringe
- Do not use this product on a sterile field
- Do not introduce any other fluid into the syringe at any time
- This product is for single dose only; discard unused portion
CAUTION: Federal (USA) law prohibits dispensing without prescription.